Quick verdict
The Fieldpiece SR47 is a wireless refrigerant scale for jobs where the cylinder stays in one place and the reading needs to be visible elsewhere. The included remote lets it work without a phone; choose it when that viewing flexibility matters, then check the complete accuracy specification against the weight changes you need to record.
Its high capacity is useful for larger cylinders, but the smallest digit on a display is not the same as measurement accuracy. Compare the complete weight specification with the size of changes you need to document. We have not tested the SR47’s accuracy, wireless reception or resistance to jobsite damage.
The jobs it suits
A technician working beside a hard-to-see cylinder may benefit more from this layout than someone who always has a clear view of a wired display. Consider actual cylinder positions, hose routes and how often readings need to enter a job record. Connectivity earns its cost when it solves a repeated problem.
Yes, the SR47 can be used without a phone: the package includes a separate wireless remote display. Job Link is another viewing option. Ask a supplier to demonstrate the arrangement you intend to use, including platform identification when several scales are nearby.
Documented specifications
The product page and v05 operator manual publish separate accuracy ranges. The following table preserves them rather than applying the smaller percentage to the whole capacity.
| Specification | Manufacturer documentation |
|---|---|
| Maximum load | 252 lb (114 kg) |
| Maximum tank base diameter | 13 inches (33 cm) |
| Specified accuracy, 0–66 lb | ±(0.03% of reading + 0.25 oz); at 73°F ±9°F and below 75% RH |
| Specified accuracy, 66–252 lb | ±(0.05% of reading + 0.25 oz); at 73°F ±9°F and below 75% RH |
| Best displayed resolution | 0.25 oz in lb/oz mode; 10 g in kg/g mode |
| Power | Six AA batteries in platform; one 9V battery in remote |
| Wireless range claim | 1,000 feet line of sight; obstructions affect distance |
Read the accuracy formula carefully
The specified accuracy includes a percentage of reading plus a fixed quantity. It is not simply one quarter ounce at any load. The stated reference conditions also matter: 73°F ±9°F, below 75% relative humidity. The manual includes a temperature coefficient for conditions away from its reference temperature.
As an illustration of the arithmetic, 0.03% of 50 lb is 0.015 lb, or 0.24 oz. Adding 0.25 oz gives approximately ±0.49 oz under the stated conditions. This calculation interprets the published formula; it is not a measurement of an SR47 or a complete uncertainty estimate for a charging job.
A scale’s specification should also be kept separate from the uncertainty of the whole procedure. If the requested record needs tighter confidence than the complete arrangement supports, more digits will not solve that problem. Choose a suitable verification method and record what was actually observed.
Capacity describes total supported weight
The maximum load applies to what the platform supports, including the cylinder. Taring a cylinder changes the displayed reference; it does not create extra physical capacity. Before selecting a scale, add the heaviest cylinder and its expected contents rather than comparing capacity with refrigerant charge alone.
Platform fit matters alongside load. Check the base of your cylinders and the space where the scale will sit. A large headline capacity has little practical value if the intended cylinder cannot rest securely in the working location. A buying demonstration with your usual cylinder type can answer that more directly than a photograph.
Setup affects the meaning of a change
The manual calls for solid, level ground and specifically addresses hose weight: connect the hoses before zeroing and note the stable final weight before removing them. Those instructions make the support arrangement part of the measurement, rather than an incidental detail.
Keep notes about the starting reference, units and final reading. For recovery work, distinguish the amount added from gross cylinder weight and follow the cylinder’s applicable filling limits. The SR47 measures weight; neither its capacity nor a tared display certifies that a recovery cylinder can safely accept more refrigerant.
SR47 wireless range and job records
The SR47 flyer describes the remote, app and related viewing features. Its line-of-sight range is a manufacturer claim, not evidence that a signal will cross every mechanical room or rooftop obstruction. Check the real connection before arranging a job around distant viewing.
For multiple scales in one shop, demonstrate identification and pairing as well as range. A reading is useful only if it belongs to the intended platform. Decide how your record will identify the cylinder, scale and observed weight change without assuming that a saved screen explains the whole job.
Ownership and replacement parts
This is a two-device battery arrangement. Keep both battery types available and inspect the remote and platform indicators before work. The published battery-life figures are typical values; they do not guarantee that partially used batteries will complete a particular job.
The product page identifies a replacement remote as RSR47D. Verify current availability, service options and seller support before purchase. We have not verified prices for a replacement remote, calibration, repairs or batteries. Include those possibilities when comparing the SR47 with a simpler scale.
Buying checklist
- Confirm SR47 model identity and the included remote, batteries and carrying case.
- Check your largest cylinder’s total weight and base dimensions.
- Compare the appropriate accuracy range and operating conditions with your measurement need.
- Demonstrate pairing, units and record keeping in the display arrangement you expect to use.
- Confirm seller authorization, returns and the repair route.
The exact-model Amazon destination does not establish seller authorization. Fieldpiece’s marketplace policy makes authorization a separate buying consideration. The SR47 is worth shortlisting when remote reading and a large platform solve a real workflow need; a simpler scale can remain a reasonable choice when those features add little value.
Manufacturer specification reference
Fieldpiece · SR47 · SR47 Wireless Refrigerant Scale
These are manufacturer specifications, not independently measured results.
- Maximum load
- 252 lb (114 kg)
- Maximum tank base diameter
- 13 inches (33 cm)
- Specified accuracy, 0–66 lb
- ±(0.03% of reading + 0.25 oz); at 73°F ±9°F and below 75% RH
- Specified accuracy, 66–252 lb
- ±(0.05% of reading + 0.25 oz); at 73°F ±9°F and below 75% RH
- Best displayed resolution
- 0.25 oz in lb/oz mode; 10 g in kg/g mode
- Power
- Six AA batteries in platform; one 9V battery in remote
- Wireless range claim
- 1,000 feet line of sight; obstructions affect distance
Related BAS Bridge learning
Sources & verification
Follow the current manufacturer instructions for your exact model. Specifications and source revisions can change.
- Fieldpiece SR47 product specifications ↗
Model identity, maximum load, tank base size, two accuracy ranges, viewing options and replacement-remote part number.
Checked Oct 29, 2026 · Source publication date: Unknown - Fieldpiece SR47 operator manual v05 ↗
Reference conditions, resolution by unit, load limits, solid-level setup, hose-weight guidance and remote/platform battery specifications.
Checked Oct 29, 2026 · Source publication date: Unknown - Fieldpiece SR47 flyer v07 ↗
Separate remote, platform layout and manufacturer viewing/range claims; not independent reception or durability testing.
Checked Oct 29, 2026 · Source publication date: Unknown - Fieldpiece online marketplace policy ↗
Marketplace seller authorization requirements.
Checked Oct 29, 2026 · Source publication date: Unknown - Amazon SR47 exact-model listing ↗
Purchase identity only: Amazon productTitle identifies Fieldpiece SR47 Wireless Scale with Remote and matching ASIN. No prices or ratings imported.
Checked Oct 29, 2026 · Source publication date: Unknown - Fieldpiece SR47 official product image ↗
Exact-model image linked from the manufacturer product page and visually checked for product identification. The image is not evidence of BAS Bridge ownership or testing.
Checked Oct 29, 2026 · Source publication date: Unknown
Editorial context
Prepared by BAS Bridge from linked manufacturer documentation and original buying analysis. This article does not claim firsthand use or independent performance measurements.
Manufacturer product information and operator documentation were checked on October 29, 2026. Practical buying conclusions are editorial analysis; no physical testing or service-call experience is claimed.
No current price, stock level, customer star rating, or measured reliability rate is implied.
Methodology & disclosure →