Service dispatch
Open a work order, investigate live equipment, then verify the repair or safety handoff.
42 work orders · — completed
Work order queue 42 of 42
| Work order | Customer complaint | Equipment | System category | Difficulty | Status |
|---|---|---|---|---|---|
| AHU-01 | The morning start produces no airflow | Air-handling unit | VFDs and motors | Foundation | Open |
| AHU-02 | One office keeps asking for more cooling | Air-handling unit | Sensors and instrumentation | Foundation | Open |
| AHU-03 | The fan is working harder while airflow falls | Air-handling unit | Airside systems | Foundation | Open |
| AHU-04 | Free cooling is requested, but mixed air stays warm | Air-handling unit | Airside systems | Intermediate | Open |
| AHU-05 | The cooling valve is fully requested, but supply air is warm | Air-handling unit | Hydronic systems | Intermediate | Open |
| AHU-06 | The displayed duct pressure stays low as the building gets noisy | Air-handling unit | Sensors and instrumentation | Intermediate | Open |
| AHU-07 | Air warms up after it leaves the cooling coil | Air-handling unit | Hydronic systems | Intermediate | Open |
| AHU-08 | Supply temperature swings despite a steady load | Air-handling unit | Sequences of operation | Advanced | Open |
| AHU-09 | The occupied schedule is active, but the fan output remains off | Air-handling unit | Controls and communications | Advanced | Open |
| AHU-10 | One zone keeps the entire AHU at high pressure | Air-handling unit | Airside systems | Advanced | Open |
| AHU-11 | The open office has no supply air | Air-handling unit | Electrical | Intermediate | Open |
| AHU-12 | The office wing stays cold during morning warm-up | Air-handling unit | Hydronic systems | Intermediate | Open |
| CH-01 | Cooling requested, startup remains on hold | Chiller | Electrical | Foundation | Open |
| CH-02 | Condenser-side permissive never arrives | Chiller | Sequences of operation | Foundation | Open |
| CH-03 | Plant graphic says stopped while cooling continues | Chiller | Controls and communications | Foundation | Open |
| CH-04 | Remote supply temperature stays above target | Chiller | Sensors and instrumentation | Intermediate | Open |
| CH-05 | Condenser water warms despite maximum tower command | Chiller | VFDs and motors | Intermediate | Open |
| CH-06 | High water flow with a small plant temperature rise | Chiller | Hydronic systems | Intermediate | Open |
| CH-07 | Lead machine is fully loaded but standby stays idle | Chiller | Sequences of operation | Intermediate | Open |
| CH-08 | Condensing temperature rises at comparable operating conditions | Chiller | Hydronic systems | Advanced | Open |
| CH-09 | Remote pressure looks satisfied while circulation is inadequate | Chiller | Sensors and instrumentation | Advanced | Open |
| CH-10 | Chilled water settles above the operator's requested target | Chiller | Controls and communications | Advanced | Open |
| BL-01 | Morning heat request without burner operation | Boiler | Sequences of operation | Foundation | Open |
| BL-02 | Circulator running while startup waits for flow | Boiler | Hydronic systems | Foundation | Open |
| BL-03 | One heating zone stays cold | Boiler | Hydronic systems | Foundation | Open |
| BL-04 | Heating water is too cool on a cold morning | Boiler | Sensors and instrumentation | Intermediate | Open |
| BL-05 | Burner repeatedly starts and stops | Boiler | Sequences of operation | Intermediate | Open |
| BL-06 | Plant capacity disappears after a lead-boiler outage | Boiler | Sequences of operation | Intermediate | Open |
| BL-07 | Boiler operates after occupied demand ends | Boiler | Controls and communications | Intermediate | Open |
| BL-08 | The boiler stays idle during the morning heat call | Boiler | Electrical | Advanced | Open |
| BL-09 | Hot boiler outlet but cooler distribution supply | Boiler | Hydronic systems | Advanced | Open |
| BL-10 | Dashboard reports cold water while local control is satisfied | Boiler | Controls and communications | Advanced | Open |
| RF-01 | The display looks satisfied, but the cooler is warm | Refrigeration system | Sensors and instrumentation | Foundation | Open |
| RF-02 | Cold near the coil, warm across the box | Refrigeration system | Electrical | Foundation | Open |
| RF-03 | The freezer gets warmer every day | Refrigeration system | Sequences of operation | Foundation | Open |
| RF-04 | Defrost starts, yet frost remains | Refrigeration system | Sequences of operation | Intermediate | Open |
| RF-05 | Cooling weakens on a mild afternoon | Refrigeration system | Refrigeration | Intermediate | Open |
| RF-06 | The compressor restarts after the cooling call ends | Refrigeration system | Refrigeration | Intermediate | Open |
| RF-10 | Temperature spikes follow the delivery window | Refrigeration system | Refrigeration | Intermediate | Open |
| RF-07 | High superheat with intermittent liquid supply | Refrigeration system | Refrigeration | Advanced | Open |
| RF-08 | The evaporator is starved despite available liquid | Refrigeration system | Refrigeration | Advanced | Open |
| RF-09 | The feed command rises, but cooling does not | Refrigeration system | Refrigeration | Advanced | Open |