Learning Center
BAS Bridge Academy
Level 1 · Absolute Beginner
Module 1 · Introduction to HVAC and building automation
Choose a starting point
Take the optional placement check
Use these five field situations to choose where to begin. You can open any level.
Guided curriculum
6 levels · 30 modules · 63 lessons
1Absolute BeginnerLevel 1 · 5 modules
Module 1Introduction to HVAC and building automationTrace a comfort complaint from an occupied room to its serving equipment.
Module 2Applied HVAC physicsUse temperature, airflow, differential pressure and moisture readings to explain heat delivery.
Module 3Commercial HVAC equipment anatomyIdentify each machine and follow the path that air, water or refrigerant takes through it.
- Inside the air-handling unit12 min
- Separate the two air paths in a rooftop unit12 min
- Follow air through a variable air volume terminal12 min
- Find what a fan-coil unit delivers to one space12 min
- Verify air leaves through an exhaust fan12 min
- Follow heat out of a hot-water boiler12 min
- Keep the two water circuits of a chiller separate12 min
- Read a cooling tower’s heat rejection12 min
- Trace a circulating pump and its branches12 min
- Follow heat out of the walk-in cooler12 min
- Compare a coil, a damper, a valve and a filter12 min
Module 4Basic electrical theoryPredict voltage, current and power in a simple circuit and identify its source and protection.
Module 5Introduction to electrical troubleshootingTrace the fan relay circuit, choose safe measurements and verify its return to service.
2Controls FundamentalsLevel 2 · 5 modules
Module 6Sensors and transmittersCompare a sensor reading with a suitable local reference at the same time and location.
Module 7Control signalsConvert a measured signal to engineering units and find where an indicated value diverges.
Module 8Actuators and final control devicesCompare a requested position with observed travel and delivered heat or air.
Module 9Motors and variable frequency drivesCompare run state, speed and independent airflow at the driven equipment.
Module 10Direct digital controlTrace a local feedback loop from sensor through controller to the final device.
3BMS OperatorLevel 3 · 6 modules
Module 11Understanding the workstationUse the equipment hierarchy, point source and time to interpret what a graphic shows.
Module 12Schedules, overrides and command ownershipLocate the effective command and verify control returns to its intended owner.
Module 13Airside system operationFollow normal fan start and air delivery before investigating a zone complaint.
Module 14Hydronic and central plant operationFollow heat from a plant through circulating water to an occupied space.
Module 15Refrigeration controlsFollow refrigeration demand, defrost and recovery in a walk-in cooler.
Module 16Alarms, trends and historical dataAlign event times and independent readings to identify the first meaningful change.
4Controls TechnicianLevel 4 · 6 modules
Module 17Systematic troubleshootingLocalize a failure and leave a diagnosis the next shift can reproduce.
Module 18Advanced field device diagnosticsUse terminal measurements, isolated resistance and travel to localize device failures.
Module 19Building automation networkingIdentify an affected network branch and compare local equipment with reported data.
Module 20BACnetIdentify the device, object and property and bound a trunk communication problem.
Module 21Modbus and system integrationUse a fictional register map and a local reading to verify a gateway translation.
Module 22Commissioning and documentationTrace the drawings, prove the point and document an operating sequence through restoration.
5Controls ProgrammerLevel 5 · 4 modules
Module 23Programming fundamentalsTrace values through a running controller and distinguish calculated values from physical outputs.
Module 24Control logic and sequence developmentPredict the effect of a missing permissive or interrupted proof timer.
Module 25PID and closed-loop controlCompare a recorded baseline with a single tuning change and identify output limitations.
Module 26Equipment programming projectsDeploy a control graph and evaluate its behavior against executable test conditions.
6Advanced Systems SpecialistLevel 6 · 4 modules
Module 27Advanced HVAC control strategiesInterpret zone requests and check ventilation and operating constraints before a reset.
Module 28Central plant optimizationCompare stages, rotation, water temperatures and load before changing plant operation.
Module 29Advanced integration, diagnostics and reliabilitySeparate stale observations from physical faults and document a recoverable change.
Module 30Building automation capstone investigationsDiagnose concurrent faults in one occupied building, prove automatic recovery under load and defend your handoff.
Guided service dispatches
Find an independent witness that air reaches the occupied area.
The BAS says the supply fan is on. Can you prove the building is receiving air? Challenge Unit 1Locate the first disagreement between the field signal, controller conversion and displayed value.
The pressure on the graphic disagrees with the field transmitter. Challenge Unit 2Separate the electrical indication, physical movement and measured delivery.
The damper shows full travel. The room still has very little air. Challenge Unit 3Predict which transition is permitted and when its proof timer starts.
The operator enabled the AHU. Should the fan have started yet? Challenge Unit 4Trace a request to its active owner and prove who takes over on release.
The schedule changed. The equipment did not. Challenge Unit 5Trace load, air and heat from the unit to the occupied zone and verify automatic recovery.
The heating valve is at 100%. Why is the discharge air still cold? Challenge Unit 6 · Rooftop heat and terminal airflowCompare the header, healthy branch and affected coil under the same load.
The supply header is hot, but the perimeter is cold. Challenge Unit 7Identify the earliest meaningful change and decide whether tuning is justified.
The discharge temperature swings above and below target. Challenge Unit 8Use local references, point age and affected devices to bound the fault.
East wing temperatures are flat on the BAS while the equipment still responds. Challenge Unit 9Leave a reproducible point-to-point, functional and restoration record.
A checkout point moves in the wrong direction under load. Challenge Unit 10Separate the initiating event from its consequences and give the next shift a retest plan.
The equipment is running normally now. What happened overnight? Challenge Unit 11Support a diagnosis, rule out an alternative and document verified recovery across systems.
Three open dispatches need field evidence and a closeout.Original module examinations
- Module 1 · Building Automation Fundamentals
- Module 2 · Electrical and Controls Fundamentals
- Module 3 · Sensors and Field Devices
- Module 4 · Control Logic and Programming
- Module 5 · HVAC Equipment Sequences
- Module 6 · Building Automation Networks
- Module 7 · Advanced HVAC Control Strategies
- Module 8 · BAS Software and Graphics
- Module 9 · Commissioning
- Module 10 · Advanced troubleshooting
- Module 11 · Professional controls technician skills
- Module 12 · Capstone training