Level 1 · Basic electrical theory

Calculate voltage, current, resistance and power

15 minutes · Foundation

Reading open · Practical open · Knowledge check open

What you’ll learn

  • Calculate current in a simple resistive DC load.
  • Explain how voltage, current and power describe different observations.
Before you start · 1 related lesson0 of 1 prerequisites demonstrated. You can open this lesson at any time.

Use a complete path

A source maintains a difference in electrical potential between two points. measures that difference in volts (V). is the rate of charge flow in amperes (A). A load uses electrical energy. A complete path allows current through the load and back to the source.

A resistor on the virtual bench

Resistance in ohms (Ω) opposes current. For a simple resistor, voltage equals current times resistance, V = I × R. Rearrange to find current, I = V ÷ R. For a DC load, in watts equals voltage across it times current through it. At 12 V a 24 Ω resistor draws 0.50 A and uses 6 W. These equations use volts and amperes; 1,000 milliamperes (mA) = 1 A.

Use the source marked on the drawing

Direct current (DC) flows in one direction under steady conditions. Alternating current (AC) reverses direction periodically. Meter modes must match the intended measurement. A real AC relay coil has impedance; its DC resistance alone cannot predict operating AC current. All readings in this lesson come from the virtual trainer.

Across the source, through the resistor, back to the source
  1. Source
  2. Resistive load
  3. Return path

Normal operation

Example training conditions

  • A 24 V DC supply across a 120 Ω resistive training load produces 0.20 A, or 200 mA.
  • At that operating point the load receives 24 × 0.20 = 4.8 W.

Worked service example

A trainee reports that a resistor uses 24 amps because the meter shows 24 V.

Recorded field evidence · training example

  • Meter is connected across the resistor on DC voltage mode and reads 24 V.
  • Resistor is specified at 240 Ω. Supply is steady.

The reading is electrical potential across the load. The predicted current is 24 ÷ 240 = 0.10 A. A simulated current observation can test the prediction. Real current measurements need the correct instrument and connection; an ammeter across a source can short it.

Terms in this lesson
Voltage
Electrical potential difference between a named pair of points.
Current
Charge per unit time through a path.
Power
Rate of energy use, measured in watts.

Hands-on exercise

Inspect a 12 V DC resistive circuit and compare the predicted and recorded current.

Predict before inspection

If the resistance doubles at the same DC voltage, how does resistive current change?

Virtual bench checkout

Verify your finding in the recorded case to open the bench.

Knowledge check

Pass at 80%. Every safety item must also pass.

1. Which meter connection must be avoided on an energized source? · Required for safety
2. Which report is incomplete if the technician gives only one terminal and omits the reference point?
3. A DC resistor has 12 V across it and carries 0.25 A. Calculate power.
4. A supply is labeled 24 VAC. Which electrical quantity alternates?
5. A steady 24 V DC supply drives a 240 Ω resistor. Calculate current.

Field takeaways

  • Name the mode, unit, connection and load before interpreting a meter number.

References and further reading